Brief introduction of precautions for the installation and use of pulse solenoid valve

1. The best installation method of electromagnetic pulse valve is vertical to the horizontal pipe and the coil is upward. When the premise is not allowed, it is allowed to tilt ± 30 °. Otherwise, normal use cannot be guaranteed

2. The parameters on the nameplate of the solenoid valve should be consistent with the actual use requirements

3. The arrow on the solenoid valve body should be consistent with the flow direction of the medium

4. To ensure the normal use of the solenoid valve, please install an oil-water separator in front of the solenoid valve

5. In order to prevent the explosion and other accidents caused by the loss of our polymer expertise in dangerous environments, explosion proof solenoid valves should be used to prevent the continuous appearance of new raw materials, new singers and new products

6. Before installation, please thoroughly purge the air bag and pipeline to avoid foreign matters damaging the diaphragm and causing solenoid valve failure

7. When the solenoid valve fails, in order to isolate in time and facilitate maintenance, it is recommended to install a bypass (bypass) device

8. When the electromagnetic pulse valve is not installed temporarily, it can be stored at 0~40 ℃, and the relative humidity ≤ 80%, but indoor without corrosive gas, avoid outdoor storage as far as possible

3. The third load range: 0 ~ 5 N times of strong pressure

9. After unpacking, check whether the use imitation list, factory certificate and packing list are complete. Then check whether the product name and model are consistent with the list, and check whether the nameplate is consistent with the purchase order. If there is any defect or discrepancy, contact the manufacturer in time